Analytical information

The information below refers to the standard cartridge supplied for a mains connected
Iceblue Water filtration system. Our system removes the following impurities:

Australian Government Analytical Laboratories South Australian Regional Laboratory

* Results expressed as micrograms/Litre (ppb)

Compound
Before filtration
After filtration
Percentage reduction
PESTICIDES
 
 
 
Dialdrin
0.55
<0.1
>98
Heptachlor
0.5
<0.1
>98
DDD
0.6
<0.1
>98
DDE
0.6
<0.1
>98
DDT
0.5
<0.1
>98
PCB Screen
2.8
<0.3
>89
Aldrin
0.5
<0.1
>98
BHC
1.6
<0.3
>81
HCB
0.57
<0.1
>98
Osychlordane
0.52
<0.1
>98
Endrin
1.35
<0.3
>76
Lindans
0.55
<0.1
>98

 

*Results below expressed as milligrams/Litre (ppm) 

METALS
 
 
 
Aluminium
0.42
<0.02
>95
Cadmium
0.043
<0.001
>98
Copper
2.9
<0.05
>98
Iron
2.2
<0.05
>98
Mercury
0.01
<0.001
>90
Lead
0.67
<0.01
>99
Zinc
3.7
<0.01
>99

 

*Results below expressed as most probably number/100ml 

MICROBIOLOGICAL
 
 
 
Yeasts (No./mL)
46000
<1
>99
Moulds (No./mL)
1500
<1
>99
E.coli (MPN/100mL)
>1,810,000
<181
 
Group D
Streptococci
>1,810,000
<181
 

 

Approximately five litres of tap water were spiked with the above compounds and pumped through the filter at 1.4L/min. Approximately three litres of filtrata were discarded prior to collection. The water was analysed before and after filtration.